2.3.1 DC Cable Connection
The PVI5000 is designed to support two independent PV strings,
string A and B.
Each PV string shall provide a DC input voltage with maximum
power of 3000 W and maximum current of 12 A. The are two (2)
terminals, labeled as “+” and “-”, DC voltage input located on the
bottom of the inverter used for the DC cable connections.
Fig. 3.3.2.1 DC terminals for DC cable connection
Connect the Positive (+) wire from the #1 PV string to the PV1
(+) terminal. Double check the wire is in the proper location
and tight it with screw.
Connect the Negative (-) wire from the #1 PV sting to the PV (-)
terminal. Double check the wire is in the proper location and
tight it with screw.
Repeat for the #2 PV string, if there is one. Double check the
wire is in the proper location and tight it with screw.